Achieving good thermal performance of a building fabric will reduce the heat loss from a building, which in turn will reduce the space heating requirements along with carbon emissions and make for improved thermal comfort of the occupants. There are many factors involved when designing for thermal performance, along with a number of variables. Here we will look at an array of factors relating to thermal elements in building design.
Heat Transfer
- Conduction
- Convection
- Radiation
k-values, r-values and u-values
In order to measure the effectiveness of the materials we specify and the suitably of a building assembly we need to look to a series of factors.
K-Value
The k-value or lambda(ƛ) value (W/mK) measures the thermal conductivity of a material. The lower the k value, the better the insulation property of a material.
Some examples of thermal conductivity would be:
R-Value
The r-value (m2K/W) measures the thermal resistance of a material or construction, and is simply the thickness of a material divided by its k-value.
The thickness and conductivity of a material contribute to the overall thermal resistance of a construction. In a building assembly, the thermal resistance is measured for each material to get the overall thermal resistance of the composite.
The higher the thermal resistance, the better the insulator. Rock wool insulation has a high thermal resistance, concrete has a low thermal resistance and is a bad insulator.
U-Value
A u-value is the measure of the overall rate of heat transfer, by all mechanisms under standard conditions, through a particular section of construction.
In the UK, the lower the u-value the better thermal performance by keeping the heat flow through the structure to a minimum.
You can read more about U-values and look at some supporting documentation and workings by going to our U value guide.
[Recommended u-values for a new dwelling]
Building regulations and standards often refer to u-values as a target for thermal performance. Currently, in the UK the Building Regulation concurrent notional dwelling requirements for u-values are as follows:
To calculate a u-value of a construction refer to this article.
Sign up to our newsletter
Make sure you don’t miss out on anything that is going on at First In Architecture – sign up to the newsletter now. No spam, no funny business, just useful stuff!
Building Form
Designing a building to have less and smaller surfaces exposed to the external environment will result in a lower heat loss and therefore less energy used for heating. Research suggests that this compact design will benefit the overall thermal performance of a building. Another thing to consider is the complexity of design. A more complicated building form will most likely have more thermal bridges, whereas a simpler form will avoid some of these thermal bridges that lead to heat loss. Building form must also be considered when designing for daylight and sunlight – we will look at this in another article.
Insulation
Specifying the correct insulation for your project will have a large impact on energy performance, along with environmental benefits.
A well insulated building will not only reduce the heating requirements in the summer, but also help to keep the building cool in summer, as long as ventilation and solar gain are controlled. For larger buildings it is often the case that more energy is used in summer cooling rather than winter heating.
Well designed insulation also reduces the risk of surface condensation because the internal surfaces are kept at room temperature which is above the dew point.
We will focus on insulation materials in a future post.
Thermal bridging and heat loss
When we consider u-values we assess the building assembly as a whole. It should however also include adjustments for thermal bridges.
A thermal bridge is an area where there is reduced insulation, which results in a higher u-value creating heat loss, potential for condensation and mould. Some research suggests that up to 25% of internal heat loss is through thermal bridges[1].
There are three main types of thermal bridge:
Repeating thermal bridges – which usually are evenly distributed through the thermal envelope – an example being timber frame studs, or steel wall ties.
Non repeating thermal bridges – usually occur around openings or where materials with different thermal conductivity meet.
Geometrical thermal bridges – these are related to the shape of the building envelope usually where planes intercept. An example of this type of thermal bridge could be a junction or corner.
Some areas that thermal bridges occur:
Recommendations for reducing thermal bridging and heat loss:
- Thermal insulation and airtightness barrier should form a continuous line
- No gaps or breaks in the thermal insulation or air barrier
- Extra attention to air tightness membrane at junctions
- Refer to best practice examples (BRE, ECDs, robust details)
- Isolate thermal bridge with insulation
- Change the geometry of the thermal bridge
[1] According to Environmental Design Pocketbook

The detail above demonstrates a floor to wall junction of good practice for insulation placement and minimising thermal bridging.
In the next post we will look at insulation materials.